The FT94X service unit contains the services, controls and
instrumentationrequiredtooperatethetubularandplateheat exchangersdescribedbelow.TheFT94Xmaybespecifiedwith either or both of the heat exchangers. Switching between the twoheatexchangerstakesamatterofseconds.
Theserviceunitcomprises:aneightinchtouchscreencontrolpanel withtherequiredcontrolsanddisplays;avariablespeedprogressive cavity product feed pump with inlet level sensor and alarm to warn of low product level; a steam-heated hot water system for product preheating; automatic steam control valves for product preheating andfinalheating;acentrifugalCIPpumpandotherfacilitiesrequired forCIPandSIP.
Sensors show product inlet, preheat, final heating and outlet temperatures.Productpreheatandfinalheatingtemperaturesareset bytheoperator.Inletandoutletproductpressureisalsoshown.
Therearevariousservicesensors:pressure,levelandtemperature– seeprocessflowdiagramfordetails.
A sophisticated data logging package enables the measured data to be recorded onto a standard Windows PC (not supplied).
Thesoftwarerecordsalltemperatures,productandsteampressures, feedpumpspeedandmanyothersensorvalues.Datafromoptional accessories (e.g. the flowmeter) is also recorded. Data may be displayed in tables and graphs (both real time and comparisons acrosspreviousruns),andmayalsobeexportedtoMSExcel.
The FT94-20 is a standard tubular heat exchanger design
using a series of concentric 316 stainless steel tubes for product preheating, final heating and cooling. In all cases the product passes down the inner tube and the heating/cooling medium passes through the annulus. Two heating tubes of 1.5 m length are used to preheat the product. Four similar tubes are used for product heating and an additional four tubes are used for product cooling.
Productisgentlypreheatedusingahotwatersystem,whichisitself heatedbysteamviaasecondaryserviceheatexchanger.Inthemain heatingsectiontheproductisindirectlyheatedusingsteamitself.
Productiscoolednormallyusingwaterorchilledwater.Thecooling sectioncanbeconfiguredtoenabletwostageswherethefirststage iswater/chilledwaterandthesecondstageiswater/glycol.
TheFT94-21isasetofstaticmixersfortwotubes.Thesesignificantly improve heat transfer with more viscous products and can be used forimprovingbothheatingandcoolingefficiency.Multiplesetscan beusedtooptimisebothheatingandcoolingperformance.
The FT94-22 product divert option enables product that has not been processed to a sufficiently high temperature to be diverted to drain thus ensuring product quality and heat treatment.
Thediverttemperatureisadjustable.Diversionisachievedusingalow hold-up twin diaphragm valve block operated by compressed air and PLCcontrolled.Divertedproductiscooledinatubularheatexchanger beforebeingledtodrain.
TheFT94-20hasaonesecondholdingtube(at50l/hr)asstandard. ContactArmfieldforlongerholdingtimes.
The FT94-30 uses the sanitary heat exchanger employing the
latest plate design for efficient heat transfer. Performance scale-up is straightforward.Thestandardunitisathreestagesystemwithpreheat (hotwater)finalheating(steam)andcooling(water/chilledwater).
The plates have a complex pressed profile to maximise turbulence
andminimisedeadzones.Thereisarelativelylargegapbetweenplates toenablehandlingofmoreviscousproducts.Theplatesarefittedwith food grade Viton paraclip gaskets for easy replacement as these are simplyclippedinplaceratherthanglued.
Anumberofoptionsareavailabletoenhancetheperformanceofthe standardplateheatexchanger.Theseoptionsinvolveadditionalplate configurations, which can be supplied and fitted or may be easily retro-fitted by theuser.
The FT94-32 homogeniser interconnecting plate enables the homogeniser to be connected downstream of the heating section. The plate is fitted into the cooling section.
The FT94-33 two-stage cooling option provides a complete additional cooling stage, which can be used in conjunction with
a chilled water/glycol supply for the best possible product cooling. Output temperatures below 5°C are possible depending on the product and the flow rate.
An interconnecting link is provided so that the two stages can be operated as a single stage when required.
TheFT94-30hasafivesecondholdingtube(at50l/hr) asstandard.ContactArmfieldforlongerholdingtimes.
Technicalspecifications
FT94X Service Unit Technical specifications |
Tubular Heat Exchanger (FT94-20) |
||
Feed pump |
Number of tubes |
10 (2 preheat, 4 heating, 4 cooling) |
|
Progressive cavity variable speed pump |
Tube diameter |
||
Solids handling |
Soft 10 mm |
(product side) |
8.1 mm |
Hard 4 mm |
Overall diameter |
22.0 mm |
|
Flow rate |
30-100 l/hr |
Length (heated) |
1.46 m |
Discharge pressure |
24 bar (max) |
Product volume |
1.0 l |
Pre-heat water system |
Material |
316 stainless steel |
|
Water capacity |
~2-3 litres |
Assembled test pressure |
30 bar |
Maximum temp |
110°C |
Working pressure |
24 bar (maximum) |
Safety cut-outs |
Low level |
Plate Heat Exchanger (FT94-30) |
|
Temperature |
Plate overall dimensions |
150 x 480mm |
|
Product pump |
Effective area per plate |
0.04m2 |
|
Pressure relief valve |
Plate thickness |
0.6mm |
|
Heating system |
Product volume |
2.5litres |
|
External steam supply |
Materials,Plates |
316 stainless steel |
|
Maximum temp |
165°C |
Gaskets |
Food grade Viton |
Relief valve (7 barg) |
Max differential test pressure |
11.5bar |
|
Product pump off |
Max balanced test pressure |
12.5bar |
|
steam valve closes |
Max working pressure |
9.6bar |
|
Max product heating duty |
17 kW |
Working temperature |
Max: 170°C |
(preheat + heating) |
Min: -4°C |
||
Number of plates |
|||
FT94-30 |
Preheating 13, Heating 6, Cooling 13 |
||
FT94-33 |
Secondary cooling 7 |